Premier Office Complex of Parma, LLC v. United States , 916 F.3d 1006 ( 2019 )


Menu:
  •   United States Court of Appeals
    for the Federal Circuit
    ______________________
    PREMIER OFFICE COMPLEX OF PARMA, LLC,
    Plaintiff-Appellant
    v.
    UNITED STATES,
    Defendant-Appellee
    ______________________
    2018-1231
    ______________________
    Appeal from the United States Court of Federal Claims
    in No. 1:14-cv-01223-EJD, Senior Judge Edward J.
    Damich.
    ______________________
    Decided: February 19, 2019
    ______________________
    PETER J. GEORGITON, Dinsmore & Shohl, LLP, Colum-
    bus, OH, argued for plaintiff-appellant. Also represented
    by PETER W. HAHN.
    ANNA BONDURANT ELEY, Commercial Litigation
    Branch, Civil Division, United States Department of Jus-
    tice, Washington, DC, argued for defendant-appellee. Also
    represented by KENNETH DINTZER, ROBERT EDWARD
    KIRSCHMAN, JR., JOSEPH H. HUNT.
    ______________________
    2                  PREMIER OFFICE COMPLEX v. UNITED STATES
    Before NEWMAN, WALLACH, and STOLL, Circuit Judges.
    STOLL, Circuit Judge.
    Premier Office Complex of Parma, LLC (“Premier”) ap-
    peals the decision of the United States Court of Federal
    Claims granting the government’s motion for summary
    judgment and denying Premier’s cross-motion for sum-
    mary judgment of liability. The contract between Premier
    and the government unambiguously requires Premier to
    provide a facility conforming to Level II security require-
    ments as set forth under Interagency Security Committee
    (“ISC”) standards. Premier’s work in constructing such a
    facility thus falls within the scope of work of the contract.
    We affirm.
    BACKGROUND
    In 2007, the Department of Veterans Affairs (“VA”)
    sought to lease space in Parma, Ohio for use as a VA out-
    patient clinic (“Parma Clinic”). It issued a pre-solicitation
    Expressions of Interest memorandum, which stated that
    the lease would be for approximately 62,000–74,000 square
    feet of space and that “[t]he selected building must comply
    with the Interagency Security Committee Security Design
    Criteria for New Federal Office Buildings and Major Mod-
    ernization Projects as well as other security guidelines,
    which will be provided during the solicitation for offers pro-
    cess.” J.A. 41.
    The VA subsequently issued Solicitation for Offers No.
    VA-101-08-RP-0034 (“SFO”) detailing the lease require-
    ments for the Parma Clinic. Section 4.2.7 of the SFO dis-
    cusses the physical security requirements of the space and
    is reproduced below:
    4.2.7 Physical Security Requirements
    Lessor shall provide the following physical security
    measures or features for the spaces or areas as
    listed below:
    PREMIER OFFICE COMPLEX v. UNITED STATES                     3
    1. The Government will determine security stand-
    ards for facilities and agency space requirements.
    Security standards will be assessed based upon ten-
    ant agency mix, size of space requirement, number
    of employees, use of the space, location of the facil-
    ity, configuration of the site and lot, and public ac-
    cess into and around the facility. The Government
    will designate a security level from Level I to Level
    IV for each space requirement. The Contracting Of-
    ficer (or the Contracting Officer’s designated repre-
    sentative) will provide the security level
    designation as part of the space requirement. A
    copy of the Government’s security standards is
    available at www.oca.gsa.gov. A single use building
    over 70,000 square feet will be a Level III Security
    Requirement.
    J.A. 92–93 (emphasis added). Section 4.2.7 also contains a
    Physical Security Table, which labels seven spaces within
    the building with their own applicable security require-
    ments. J.A. 93.
    During a pre-bid meeting, a bidder asked for clarifica-
    tion on whether the SFO’s Level III security requirement
    was actually a Level II requirement. On June 3, 2008, the
    VA issued Amendment #1 to the SFO to clarify this issue
    and others. Amendment #1 states in part:
    4. Security Level – Clarify whether the project
    requires Level 2 or 3 security.
    Based upon ISC Standards, the project would be a
    Level 2, based on 11–150 personnel and a size of
    2,500 to 80,000 rentable square feet.
    J.A. 192. Amendment #1 did not define “ISC Standards” or
    reference any documents containing the ISC standards.
    On June 10, 2008, Premier signed an acknowledgement of
    receipt of Amendment #1. J.A. 193.
    4                 PREMIER OFFICE COMPLEX v. UNITED STATES
    In response to the SFO as amended, Premier submitted
    a proposed design narrative for the Parma Clinic. The de-
    sign narrative described the site development, building,
    and building systems proposed by Premier, and also con-
    sidered “at a conceptual level,” issues such as configura-
    tion, structural systems, and interior design. J.A. 198. The
    design narrative did not address the physical security re-
    quirements described in Amendment #1. See generally
    J.A. 198–209.
    On November 12, 2008, Premier and the VA entered
    into Lease No. VA-101-08-RP-0034 (the “Lease”), under
    which Premier was to provide “[a] fully built out space as
    described, all services, maintenance, operations, altera-
    tions and other considerations as set forth in Solicitation
    for Offers No. VA-101-08-RP-0034 and all amendments.”
    J.A. 46 (emphasis added). The Lease incorporated and at-
    tached the SFO, Amendments #1–3 to the SFO, Premier’s
    response to the SFO and Amendments #1–3, and Premier’s
    proposed building plan. J.A. 47.
    On March 3, 2010—nearly one and a half years after
    execution of the Lease—the VA wrote a memorandum to
    Premier inquiring about “several areas of concern” that the
    VA had regarding Premier’s first design submittal. J.A.
    359. The memorandum asked “[h]ow will the Interagency
    Security Committee (ISC) Security Design Criteria be ad-
    dressed such as progressive collapse? Refer to SFO sec-
    tion 4.2.7 and amendment #1.” J.A. 360. In a separate
    communication, the VA advised Premier to obtain access to
    the ISC standards and explained that “the project needs to
    be designed according to the ISC.” J.A. 362.
    On March 9, 2010, Premier wrote to ISC to request ac-
    cess to the standards. The ISC denied Premier’s request
    the following day and informed Premier that release of ISC
    documents “may only be made to Federal, state, or local
    government entities,” and that the documents had to be re-
    quested by a federal contracting officer who has a “need to
    PREMIER OFFICE COMPLEX v. UNITED STATES                    5
    know” the information. J.A. 363. The VA obtained copies
    of three ISC documents and, on March 16, 2010, electroni-
    cally sent them to Premier, noting that the documents are
    what Premier “will need for the VA security issues.” J.A.
    217. The three ISC documents were: (1) ISC Security De-
    sign Criteria for New Federal Office Buildings and Major
    Modernization Projects; (2) ISC Security Standards for
    Leased Space; and (3) Facility Security Level Determina-
    tions for Federal Facilities, An ISC Standard. J.A. 217,
    219, 321, 338.
    Shortly after the VA sent the ISC documents to Prem-
    ier, some confusion ensued as to which security standard
    applied to the Parma Clinic facility. Reversing course on
    previous communications, the VA instructed Premier to
    disregard the ISC requirements in the SFO and to incorpo-
    rate only the requirements as indicated in the latest VA
    Physical Security Guide. See J.A. 365–66. On March 26,
    2010, the VA electronically sent to Premier a copy of the
    VA Life-Safety Protected Design Guide, which it noted “is
    more straight forward than the ISC and should have been
    included in the SFO.” J.A. 367. On April 2, 2010, the VA
    reiterated in a memorandum that the facility should be de-
    signed “according to the VA Life-Safety Protected Design
    Manual.” J.A. 370. Several months later, however, the VA
    again changed its position. Specifically, on July 26, 2010,
    the VA wrote to Premier advising that “[t]he ISC is the de-
    sign standard, and the facility should be designed with that
    criteria.” J.A. 372.
    On October 26, 2010, Premier sought clarification on
    whether the ISC Level II requirements applied to the en-
    tire facility. See J.A. 378. Premier’s stated understanding
    was that only the individual spaces listed in Section 4.2.7’s
    Physical Security Table needed to comply with the ISC.
    Premier noted that there would be significant additional
    costs associated with applying the ISC standard to spaces
    beyond those listed in the Physical Security Table and
    asked if the VA intended to pay for the additional costs.
    6                 PREMIER OFFICE COMPLEX v. UNITED STATES
    See J.A. 378. The VA responded on October 29, 2010, in-
    structing Premier that the project “must conform to the
    ISC Level II Security Requirement at no additional cost to
    the government.” J.A. 379. It noted that the ISC standard
    was “available upon request prior to bid,” and that “it per-
    tains to an entire building not individual rooms.” J.A. 379.
    Although Premier disagreed with this position, it eventu-
    ally designed and constructed the building in accordance
    with the ISC standards. See Premier Office Complex of
    Parma, LLC v. United States, 
    134 Fed. Cl. 83
    , 86 (2017)
    (“Decision”) (citing Complaint ¶ 18, Premier Office Com-
    plex of Parma, LLC v. United States, 
    134 Fed. Cl. 83
     (2017)
    (No. 14-1223C) (“Complaint”)).
    On February 14, 2011, Premier wrote to the VA asking
    for a determination regarding the Parma Clinic’s physical
    security requirements. On November 1, 2011, Premier’s
    counsel sent a letter to the VA requesting $964,356.40 for
    additional costs incurred by Premier as a result of the VA’s
    alleged changes to the lease. See J.A. 382. According to
    Premier, the VA’s addition of the ISC security require-
    ments “substantially increased” Premier’s costs to design
    and construct the Parma Clinic. J.A. 382. On December 5,
    2011, the VA issued a final determination and denied
    Premier’s request for payment. It explained that “the
    building security requirements were clearly spelled out
    within the SFO in section 4.2.7 and then clearly confirmed
    in Amendment #1 prior to the Lessor providing a bid and
    receiving the award.” J.A. 395. On February 11, 2014,
    Premier’s counsel submitted a certified claim for payment
    to which the VA did not respond. On December 22, 2014,
    Premier filed the current lawsuit in the Court of Federal
    Claims, alleging that the VA breached the Lease by direct-
    ing Premier to perform work outside the scope of the con-
    tract and refusing to compensate Premier for the extra
    costs. See Complaint ¶¶ 5–7.
    On cross motions for summary judgment, the Court of
    Federal Claims ruled that the Lease as a whole “provided
    PREMIER OFFICE COMPLEX v. UNITED STATES                     7
    that ISC Standard Level II applied to the entire facility.”
    Decision, 134 Fed. Cl. at 90. It determined that while Sec-
    tion 4.2.7 itself was latently ambiguous, Amendment #1 re-
    solved the ambiguity as it “clearly requires ISC Level II
    security for the whole ‘project.’” Id. at 89–90. The Court of
    Federal Claims rejected Premier’s argument that the ISC
    standards applied only to the spaces listed in Section
    4.2.7’s Physical Security Table, explaining that the plain
    meaning of “project” compels the conclusion that the stand-
    ards applied to the entire facility. See id. at 90. It further
    noted that “had Premier consulted the ISC Standards in a
    timely manner, it would have seen this discrepancy and not
    fallen into the misconception that the ISC Standards only
    applied to the spaces and areas listed on the table.” Id. at
    89–90. Accordingly, the Court of Federal Claims granted
    the government’s motion for summary judgment and de-
    nied Premier’s cross motion for summary judgment of lia-
    bility. Id. Premier appeals. We have jurisdiction under
    
    28 U.S.C. § 1295
    (a)(3).
    DISCUSSION
    I
    “We review ‘the summary judgment of the Court of
    Federal Claims, as well as its interpretation and applica-
    tion of the governing law, de novo.’” Hartman v. United
    States, 
    694 F.3d 96
    , 101 (Fed. Cir. 2012) (quoting Gump v.
    United States, 
    86 F.3d 1126
    , 1127 (Fed. Cir. 1996)). The
    Rules of the Court of Federal Claims (“RCFC”) provide that
    summary judgment is appropriate “if the movant shows
    that there is no genuine dispute as to any material fact and
    the movant is entitled to judgment as a matter of law.”
    RCFC 56(a); see also Celotex Corp. v. Catrett, 
    477 U.S. 317
    ,
    322 (1986). “Contract interpretation is a question of law
    generally amenable to summary judgment.” Varilease
    Tech. Grp., Inc. v. United States, 
    289 F.3d 795
    , 798 (Fed.
    Cir. 2002). “Whether a contract provision is ambiguous is
    also a question of law.” NVT Techs., Inc. v. United States,
    8                  PREMIER OFFICE COMPLEX v. UNITED STATES
    
    370 F.3d 1153
    , 1159 (Fed. Cir. 2004) (citing Cmty. Heating
    & Plumbing Co. v. Kelso, 
    987 F.2d 1575
    , 1579 (Fed. Cir.
    1993)).
    II
    The issue before us is whether the Lease requires that
    the entire Parma Clinic facility conform to ISC Level II.
    We hold that it does. Amendment #1 was issued prior to
    execution of the Lease and was expressly incorporated into
    the Lease; it is part of the contract. See J.A. 46–47, 191–
    93. Any ambiguity that may have existed in Section 4.2.7
    was resolved by Amendment #1, which is unambiguous
    and requires ISC Level II for the “project.” The plain mean-
    ing of “project” leads us to conclude that the Lease requires
    ISC Level II for the entire Parma Clinic facility. Premier’s
    work in designing and constructing such a facility is thus
    within the scope of work of the Lease.
    When interpreting a disputed contract provision, we
    first determine whether the provision is unambiguous, or
    if it is susceptible to more than one reasonable interpreta-
    tion. See McAbee Const., Inc. v. United States, 
    97 F.3d 1431
    , 1434–35 (Fed. Cir. 1996). Our analysis begins with
    the language of the written agreement. See NVT Techs.,
    
    370 F.3d at 1159
    . “When interpreting the contract, the doc-
    ument must be considered as a whole and interpreted so as
    to harmonize and give reasonable meaning to all of its
    parts.” 
    Id.
     (citing McAbee, 
    97 F.3d at
    1434–35). If a con-
    tract provision is clear and unambiguous, the court may
    not resort to extrinsic evidence to interpret it. McAbee,
    
    97 F.3d at 1435
    . “A contract term is unambiguous if there
    is only one reasonable interpretation.” C. Sanchez & Son,
    Inc. v. United States, 
    6 F.3d 1539
    , 1544 (Fed. Cir. 1993).
    “To show an ambiguity it is not enough that the parties dif-
    fer in their respective interpretations of a contract term,”
    rather, both interpretations must be reasonable. Metric
    Constructors, Inc. v. Nat’l Aeronautics & Space Admin.,
    
    169 F.3d 747
    , 751 (Fed. Cir. 1999) (citing Cmty. Heating,
    PREMIER OFFICE COMPLEX v. UNITED STATES                      9
    
    987 F.2d at 1578
    ). “When the contractual language is un-
    ambiguous on its face, our inquiry ends and the plain lan-
    guage of the Agreement controls.” Coast Fed. Bank, FSB
    v. United States, 
    323 F.3d 1035
    , 1040–41 (Fed. Cir. 2003).
    Section 4.2.7 of the SFO addresses the Parma Clinic’s
    physical security requirements. The language in this sec-
    tion suggests some ambiguity, as it refers to physical secu-
    rity requirements in terms of spaces, facilities, and
    buildings. It states that “[l]essor shall provide the follow-
    ing physical security measures or features for the spaces or
    areas as listed below.” J.A. 92 (emphasis added). It then
    states that “[t]he Government will determine security
    standards for facilities and agency space requirements. Se-
    curity standards will be assessed based upon . . . location
    of the facility, configuration of the site and lot, and public
    access into and around the facility.” J.A. 93 (emphases
    added). The section continues: “[t]he Government will des-
    ignate a security level from Level I to Level IV for each
    space requirement . . . . A single use building over 70,000
    square feet will be a Level III security requirement.” 
    Id.
    (emphases added). Section 4.2.7 then shows a Physical Se-
    curity Table, which labels seven spaces within the building
    with their own applicable security requirements. 
    Id.
    Amendment #1 was issued in part to clarify Sec-
    tion 4.2.7, specifically, to “[c]larify whether the project re-
    quires Level 2 or 3 security.” J.A. 192 (emphasis added).
    Amendment #1 explains that “[b]ased upon the ISC Stand-
    ards, the project would be a Level II.” 
    Id.
     Premier argues
    that Amendment #1 “is itself ambiguous” and that it ap-
    plies only to the seven specific areas identified in Section
    4.2.7’s Physical Security Table. Appellant Br. 21–22. Ac-
    cording to Premier, Section 4.2.7 requires physical security
    enhancements for only seven areas, so Amendment #1,
    which clarified Section 4.2.7, should also apply only to
    those areas. Id. at 19, 21–23. The government’s position
    is that Amendment #1 is unambiguous and requires the
    10                 PREMIER OFFICE COMPLEX v. UNITED STATES
    entire facility to conform to ISC Level II. Appellee Br. 9–
    12. We agree with the government.
    Amendment #1 clearly requires ISC Level II for the
    “project.” The only reasonable interpretation of this lan-
    guage is that “project” refers to the entire Parma Clinic fa-
    cility. Because Amendment #1 was issued to clarify the
    seemingly ambiguous Section 4.2.7, it is reasonable to in-
    terpret Amendment #1 as applying to the entire facility.
    This reading clarifies all of Section 4.2.7—the facility,
    spaces, and building must all conform to ISC Level II. This
    interpretation is consistent with the plain meaning of the
    term “project,” which is defined as “[a]n individual or col-
    laborative enterprise that is carefully planned to achieve a
    particular aim.” OED, Project, English Oxford Living Dic-
    tionaries (Dec. 13, 2018, 12:01 PM), https://en.oxforddic-
    tionaries.com/definition/project. We agree with the Court
    of Federal Claims that the aim of the collaborative enter-
    prise here is the construction and lease of the Parma Clinic
    facility. See Decision, 134 Fed. Cl. at 90. To interpret
    Amendment #1 as Premier proposes would mean that “pro-
    ject” refers to only a subset of spaces within the collabora-
    tive enterprise. This is an unreasonable reading. We
    conclude that Amendment #1 unambiguously requires the
    entire Parma Clinic facility to conform to ISC Level II.
    Premier was on notice prior to the signing of the Lease
    that the ISC standards would be required. Amendment #1
    issued on June 3, 2008, Premier signed an acknowledge-
    ment of receipt of Amendment #1 on June 10, 2008, and the
    parties signed the Lease, which expressly incorporated
    Amendment #1, on November 12, 2008. See J.A. 47, 191–
    193. There is no evidence in the record that Premier ever
    inquired about the scope and applicability of the ISC stand-
    ards before it signed the Lease.          It was not until
    March 2010—nearly one-and-a-half years after the Lease
    was signed—that Premier attempted to access the ISC
    standards for the first time. It took the VA only six days to
    PREMIER OFFICE COMPLEX v. UNITED STATES                  11
    deliver the standards to Premier after Premier’s initial re-
    quest was denied. See J.A. 217, 363–64.
    Had Premier requested the standards earlier—ideally
    before it even signed the Lease—it would have discovered
    that ISC security levels are determined based on charac-
    teristics of the facility, and not individual spaces. One of
    the ISC documents that the VA sent to Premier instructs
    that “[a] Level II facility has between 11 and 150 federal
    employees. In addition, the facility likely has: From 2,500
    to 80,000 square feet.” J.A. 332 (emphases added). An-
    other ISC document sent to Premier contains a chart ex-
    plaining how “ISC Facility Security Level[s]” are
    determined. See J.A. 347 (emphasis added). It shows that
    “Facility Population” and “Facility Size” are among the rel-
    evant factors that are used to determine the applicable “Fa-
    cility Security Level” ranging from I to IV. See J.A. 347.
    We recognize that after the Lease was signed, the VA
    made inconsistent statements about whether the ISC
    standards applied. These statements do not change our
    conclusion that there is only one reasonable way to inter-
    pret the Lease. In the end, the VA did communicate to
    Premier that the ISC standards applied to the Parma
    Clinic. See J.A. 372.
    Because the Lease as a whole requires ISC Level II for
    the entire Parma Clinic facility, we hold that the Court of
    Federal Claims properly determined that Premier’s work
    in providing such a facility is within the scope of work of
    the Lease.
    CONCLUSION
    We have considered Premier’s remaining arguments
    and find them unpersuasive. We affirm the judgment of
    the Court of Federal Claims granting the government’s mo-
    tion for summary judgment and denying Premier’s cross
    motion for summary judgment of liability.
    AFFIRMED
    12               PREMIER OFFICE COMPLEX v. UNITED STATES
    COSTS
    No costs.